Installing a Toilet Under Stairs — Challenges & Solutions
When planning to put a toilet underneath a staircase, you often encounter plumbing constraints. Unlike a typical bathroom located adjacent to main soil stacks or drains, an under‑stairs toilet may be:
Below the level of the main soil stack or sewer line
Far from vertical and horizontal drainage runs
Difficult to connect with large-diameter gravity pipes
Lacking natural fall (gravity drop) for waste
Hence, conventional plumbing methods (i.e. using large-diameter waste pipes sloping downwards) might not be viable without major structural work (digging, lowering floors, or rerouting drains).
This is where macerating / pump systems become extremely useful. These systems can chop (macerate) the waste to a slurry and then pump it through smaller-diameter pipes, uphill or over distance, to the main drain line.
Saniflo offers a range of macerator / pump units designed exactly for such challenging installations. For example:
Their “External Macerator Pumps” let you install a toilet (and optionally other sanitary fixtures) almost anywhere, regardless of distance to the main drain.
The Saniflo UP is promoted for slimline installs behind WCs, with pumping capacity up to 5 m vertically and up to 100 m horizontally.
The Sanitop Up is explicitly marketed for under‑stairs installations.
For installations where multiple fixtures (wc + basin + shower) are involved, models like Sanipro Up or Saniplus UP are offered.
Saniflo’s website even has a guide titled “installing toilet under stairs”, describing the benefits and how macerating/pumping solves the plumbing constraints.
How the Saniflo / Macerator Pump System Works
Here’s a simplified breakdown:
Maceration / grinding: When the toilet is flushed, solid waste (plus toilet paper) enters a small chamber where rotating blades chop it into fine particles (liquid/slurry).
Elevation & run length: The water pump can lift against vertical rises and traverse horizontal distance before connecting to the main drainage run. The specs (max vertical lift, horizontal run) depend on the particular unit.
Non‑return / check valve: There is usually a non-return valve in the discharge path to prevent backflow.
Vent / air relief: Some designs incorporate or require venting to avoid vacuum or backpressure issues.
Control & activation: The pump is typically activated by the flush flow or a micro-switch; once the flush is over, the pump stops.
One of the advantages is the ability to use smaller-diameter discharge pipes, avoiding heavy rework of large-bore plumbing.
Key Considerations & Best Practices
When planning such an installation (especially under stairs), careful attention to detail is essential to ensure reliability and compliance. Below are key points you should mind.
1. Spec the correct pump / model
Choose a unit whose vertical lift and horizontal run capabilities exceed the needed distances in your install. For example, many Saniflo Up models can push 5 m vertically and 100 m horizontally.
If you're tying multiple sanitary fixtures (WC + basin + shower) into the unit, choose a model that can accept multiple inlets and has adequate capacity (e.g. Sanipro Up, Saniplus UP).
Ensure the discharge pipe diameter is acceptable per the unit spec (often 22‑32 mm).
Ensure the motor capacity, duty rating and duty cycle are fit for your usage (residential use, frequency, etc.).
2. Positioning & clearances
The pump (macerator housing) is often located directly behind the toilet or within a shallow cavity behind/underneath.
Leave enough clearance for maintenance access (removal of clogs, descaling, servicing).
Use anti-vibration mounts or pads to reduce noise/vibration transmission.
Don’t mount the pump in contact with rigid masonry where vibration can propagate.
3. Piping layout
Always run vertical lift first before horizontal run where possible (many units are more efficient when discharging upward initially).
Avoid excessive horizontal runs or too many bends, which increase resistance.
Maintain good support and gradient for horizontal sections (even though pump is doing the push, undue sag or dips can trap solids or create blockages).
Install check valves to prevent backflow.
If the line discharges into a soil stack or sewer, that connection must comply with local plumbing codes.
4. Venting
Some macerator systems may require ventilation to avoid pressure/ vacuum issues, depending on design.
If the under stairs location cannot have a direct vent through the wall, ensure air relief or vent strategies are considered.
5. Electrical and safety
Provide a dedicated, protected electrical circuit, making sure wiring and compliance with building regulations (electrical and plumbing) are respected.
The unit should be accessible for electrical disconnection during service.
Seal all penetrations for pipes and wiring to maintain fire safety separation in stair zones (where stairs often require fire-rated partitions).
6. Maintenance, descaling & warranty
The unit should be descaled periodically to prevent scale buildup, which can impair pump performance or float switch operation.
Use the manufacturer-recommended descaler (e.g. Saniflo descaler) rather than strong acid/chemical drain cleaners that could damage internal parts.
The standard warranty for many Saniflo units is 2 years; extended 5-year warranty is often available when you register the product shortly after installation.
7. Compliance & permits
Always check local Irish plumbing and building regulations (and in your municipality) to ensure macerator toilets are allowed, and that the discharge meets wastewater code.
In some regions, inspectors may question non-traditional systems — be ready to present manufacturer documentation and compliance specs. (Some homeowners have faced objections from inspectors who claimed macerating toilets are not “code”, though this often comes down to local interpretation).
The Saniflo FAQ notes that appliances with a macerator must discharge into the “blackwater network” (i.e. main sewer) and not into greywater lines.
Water Booster Pumps / Pressure Considerations
While the macerator pumps deal with waste discharge, the water supply side (fresh water to the toilet or washbasin) must also have adequate pressure. In cases where the water pressure is low, you might consider a water booster pumps ireland.
Saniflo’s FAQ mentions that for their integrated models (e.g. Sanicompact), a minimum water pressure of about 1.7 bar is required to operate properly. If your source pressure is lower, a booster pump may be needed.
In general, a domestic booster pump or pressure-boosting unit (e.g. variable speed pump or domestic booster sets) can be installed in the cold water supply line to raise pressure to the needed level.
The booster must be sized to supply adequate flow (litres per minute) to all fixtures (toilet flush, basin, maybe shower) without causing undue surge or noise.
Pump placement should ensure minimal head loss and avoid cavitation issues.
The plumbing must include backflow protection (e.g. check valves, pressure relief) and conform to Irish water supply regulations.
Steps to a Successful Under‑Stairs Toilet Installation via Saniflo
Here’s a rough roadmap:
Site survey & layout planning
• Determine distances: vertical rise needed, horizontal run to nearest drain tie‑in
• Check structural constraints in under stairs cavity (height, depth, wall structure, fire separation)
• Evaluate water supply pressure and whether a booster is neededSelect appropriate Saniflo / macerator pump model
• Based on lift/run, number of fixtures, capacity, and clearance for maintenanceDesign the discharge plumbing
• Plan vertical-first then horizontal route, minimal bends, correct pipe diameter
• Locate check valve, vent connection if required
• Route through walls/floors with proper sealing and fire protectionDesign/upgrade water supply
• If pressure is low, select and install booster pump, with proper controls and safety devicesElectrical wiring & safety
• Dedicated circuit, isolation switch, compliance with electrical and building codeInstall sanitary fixtures & macerator unit
• Fit WC, connect inlet to macerator unit
• Mount the macerator securely, with vibration isolation
• Run discharge piping and connect to main drain
• Connect water supply (and booster if used)
• Ensure venting, check valves, clean-outs are in placeTesting & commissioning
• Flush multiple times, check that pump runs and stops properly
• Inspect for leaks, check for backflow
• Monitor noise, vibration, and check valve operationUser briefing & maintenance schedule
• Inform client of do’s/don’ts (no wipes, non‑flushable items, etc.)
• Schedule descaling intervals
• Keep manufacturer docs and warranty registration
Benefits
Enables adding a WC (or small bathroom) in unused under-stair space without reworking major drainage infrastructure.
Flexible routing of small-diameter pipes; eliminates need for large regrading.
Compact units can be concealed and keep aesthetics.
Adds convenience for inhabitants (e.g. a downstairs loo).
Conclusion
Installing a toilet under stairs is often thought to be too difficult or expensive, because traditional gravity plumbing constraints make it prohibitive. However, macerator/pump systems — such as those sold by Saniflo through its Irish distributor, Saniflo Sales — provide a practical, elegant, and proven way to overcome those constraints.
By grinding waste and pumping it through small-diameter discharge lines, these systems allow you to locate a WC in non‑ideal positions — under stairs, in basements, remote rooms — without heavy structural rework. Coupled with attention to proper model selection, piping layout, venting, electrical arrangement, and maintenance, such installations can be highly successful and reliable.
If you like, I can prepare a localized version (for Ireland / specific counties) or even a field‑guide/checklist for installers. Would you like me to do that?